Mimix Partial Database meaning

5 pts.
Tags:
AS/400
MIMIX
After issuing the WRKDG see one of the databases with a red P on it. What does that mean and how to remedy it?
1

Answer Wiki

Thanks. We'll let you know when a new response is added.

The RED P status indicator means that a process is only Partially Active.
(Satus Code Legend can be displayed with F10 from WRKDG display).
You can try to End and Restart the DG, or try to restart the process that lists the P.
This is done by modifying the “Start Process” parameter on the STRDG command prompt. Setting the value to *ALL will also do no harm as MiMiX will only try to start processes that are not active.

Discuss This Question:  

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.