The Virtualization Room

Mar 3 2008   5:30PM GMT

OEM + old machine + P2V migration = Murphy’s law

Joseph Foran Profile: Joe Foran

OK, I had a foul up in my last post about my physical-to-virtual (P2V) migration journey. I used Vizioncore’s vConverter in my file server P2V migration, and it didn’t work. I then posted PlateSpin’s product name with Vizioncore’s product name (i.e. PlateSpin vConverter) as if there were some merger from the great beyond, rather than doing the simple thing and actually editing my own posts for accuracy. It’s all been edited out correctly now, but for full disclosure purposes, there was indeed a company name and product name mix up.

Now, that said, I’ve used both products on other OEM boxes and they went just fine, so take it for what it is: a singular experience and the nature of blogging (and working with editors… that “no thanks to” line was not mine).

I seem to have a hard time with company names… I previously used incorrect capitalization for eGenera (it’s actually Egenera) some time back, and I often refer to Openfiler as OpenFiler.

Back to the tale… The domain controller from hell – a Windows 2000 server with OEM disk drivers, OEM RAID controller management tools, OEM disk management tools, and OEM network management tools. A machine nearly as old as my oldest child, one that shipped with Windows 2000 before there were service packs. It has had patches, service packs, driver roll-ups, OEM driver updates, and (probably) chocolate sauce slathered onto it in it’s lifetime.

It has also had so many applications added and removed that I think I could actually hear grinding from worn spots in the registry and creaking from the drive platters. Needless to say, this DC was spiraling down into the vortex at the end of usefulness. That’s not to say it wasn’t a great machine for a long time, but with full disks and a gurgling CPU, the poor thing was about done. It still doesn’t beat the teenagers I decommissioned early in 2007 – pair of Novell 4.11 boxes that were old enough to drive (well, with a Learner’s Permit anyway). Gotta love longevity.

First order of business: a little cleanup. Backup. Backup again to a second location. Remove IIS (it’s not used anymore). Remove an extraneous antivirus management console (a competing product is in use, this one’s just dead weight). Dump the temp files. Wipe out randomly saved setup files for applications like Acrobat Reader. Compress what I can. Defragment.

Finally, enough free space is there to support the VMware Converter agent. Lets try that and see how it goes (often, it’s the only tool I need). Failure. Hours of waiting are gone, even though the conversion hit 100% and claimed success. Turns out there’s an invisible OEM partition sitting out there that the OEM tools don’t show, and said partition has hosed the boot device order on the new virtual machine (VM). What do I see – the Blue Screen of Death (BSOD), pointing me to INACCESSIBLE_BOOT_DEVICE.

Not a huge deal, right? Just edit the boot.ini, right? No need to worry about that missing partition, right? Nope. Sure, I try to repair it by mounting to a good VM and going into the disk to edit the ini file. No luck. Ok, lets get rid of the driver. We can see the partition. Done. Now lets try again.

Failure. Are we sensing a pattern here? Same BSOD. Just like the first time, Converter goes 100% and the box BSODs on boot again. So, now that the disk management tools are no longer hiding the OEM partition, I edit boot.ini to get rid of the partition, make sure that the partition is unchecked in Converter, and try again. It succeeds!

Kind of. It’s slower than molasses in the Minnesota winter, that kind of winter where all you want to do is sit inside by the fire and let the good folks out at — sorry, for a minute there I was channeling my inner Garrison Keillor. I’m back. It’s drivers.

The OEM RAID drivers are still in there, but they are easy to strip. And it even boots up again and runs. There’s no network though. OEM NIC drivers get the strip next, but still no network (as expected). Reinstalling the VMware tools to replace the drivers doesn’t help. Next step is to shut down the VM, remove the NIC, boot again, and then add in a new NIC.

Hosed. Now the machine boots up, but it won’t let me log on. The OS is toast, and I’m not whipping out the recovery CD.

Time to pull out another product. Vizioncore’s vConverter, an acquisition from Invirtus that’s stable, robust, and more feature-rich than VMware’s offering. Redo the P2V with this tool. Same problems with the boot screen.

And there it sits for a day, in limbo, while I spend some time on Google, TechTarget, and VMware’s websites.

Finally, it’s all together… AD is corrupt. Somewhere in all that stripping of drivers, I’ve whacked Active Directory. Ok, lets fix that: Start over. Whack the VM. Re-backup. Run DCPROMO and demote the server so that it’s no longer a Domain Controller.

Time to P2V – I used vConverter again, but edited the VM before boot so that there’s no NIC. I boot it, and remove all the OEM drivers then add in the NIC. It boots. It runs. It flies. No need to robocopy. All the apps are in place and running. It just hums along happily and serves it’s purpose.

Murphy’s law: Whatever can go wrong, will.

2  Comments on this Post

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when other members comment.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • Joe Foran
    Did the OEM boxes you converted have OEM licenses installed? If so, did you have any issues post conversion with Windows requiring reactivation? I'm trying to convert the OEM license to a VLA. Doing a repair/in-place upgrade of the OS after the conversion appears to blow away a number of ACLS.
    0 pointsBadges:
    report
  • Joe Foran
    That's very interesting. This time you have put a good effort. Removing OEM drivers from P2V and then adding NICs helped you better running all the applications.
    0 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to: