Network technologies and trends

Jun 11 2012   5:04AM GMT

What is the error “BUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD” in Cisco 6500 Series Switch? – part 1

Yasir Irfan Yasir Irfan Profile: Yasir Irfan

We have plenty of Cisco Catalyst 6500 E Series Switches, recently an error appeared in the one of Cisco Catalyst 6513 Switch. When I checked the log I found the following error.

SL02-MB-1256-005#show log

Log Buffer (8192 bytes):

BUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD

Jun  7 16:47:27.446: %EARL_L2_ASIC-DFC9-4-DBUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD

Jun  7 16:48:28.582: %EARL_L2_ASIC-DFC9-4-DBUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD

Jun  7 16:49:28.971: %EARL_L2_ASIC-DFC9-4-DBUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD

Jun  7 16:50:29.723: %EARL_L2_ASIC-DFC9-4-DBUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD

Immediately I checked the status of modules and figured out the following

SL02-MB-1256-005#                  show module

Mod Ports Card Type                              Model              Serial No.

— —– ————————————– —————— ———–

1    1  Application Control Engine Module      ACE20-MOD-K9       XXXXXXXXXXX

7    2  Supervisor Engine 720 (Active)         WS-SUP720-3B       XXXXXXXXXXX

9    8  CEF720 8 port 10GE with DFC            WS-X6708-10GE      XXXXXXXXXXX

11   10  WiSM WLAN Service Module               WS-SVC-WISM-1-K9   XXXXXXXXXXX

13   10  WiSM WLAN Service Module               WS-SVC-WISM-1-K9   XXXXXXXXXXX


Mod  Sub-Module                  Model              Serial       Hw     Status

—- ————————— —————— ———– ——- ——-

7  Policy Feature Card 3       WS-F6K-PFC3B       XXXXXXXXXXX  1.0    Ok

7  MSFC3 Daughterboard         WS-SUP720          XXXXXXXXXXX  2.1    Ok

9  Distributed Forwarding Card WS-F6700-DFC3C     XXXXXXXXXXX  1.4    Ok

11  Centralized Forwarding Card WS-SVC-WISM-1-K9-D XXXXXXXXXXX  2.2    Ok

13  Centralized Forwarding Card WS-SVC-WISM-1-K9-D XXXXXXXXXXX  2.2    Ok


Mod  Online Diag Status

—- ——————-

1  Pass

7  Pass

9  Minor Error

11  Pass

13  Pass

SL02-MB-1256-005#

From the above log it’s quite evident the Cisco Catalyst 6500 Series 8-Port 10 Gigabit Ethernet Module inserted in the slot is no 9 is defective.

The error “BUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error occurred. Ctrl1 0x930D0EBD, Jun  7 16:47:27.446: %EARL_L2_ASIC-DFC9-4-DBUS_HDR_ERR: EARL L2 ASIC #0: Dbus Hdr. Error” means that the EARL L2 ASIC detected an invalid header on DBus, and it could be a faulty Cisco Catalyst 6500 Series 8-Port 10 Gigabit Ethernet Module.

In my next post I will update you the initial action plan I followed before contacting the Cisco TAC.

2  Comments on this Post

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when other members comment.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • 4321admin
    Hello yasirifan, did you sort out this problem? Is there any debug or show command that can help you in debugging this?Thanks,Enrico
    0 pointsBadges:
    report
  • Yasir Irfan
    Please check my next post
    5,535 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.