0 pts.
 z/OS CICS COBOL load module linked RENT, REUS, AMODE(31),RMODE(ANY) with statically linked AMODE(24),RMODE(24) modules.
If an executable load module has attributes of AMODE=31, RMODE=ANY, and it has modules statically linked into it with AMODE=24, RMODE=24, will the load module run above the line?

Software/Hardware used:
ASKED: February 22, 2005  4:45 PM
UPDATED: February 25, 2005  8:36 AM

Answer Wiki:
The module will be loaded above the line, but will take an S0C4 the first time it passes an above the line address to one of its 24-bit linked modules.
Last Wiki Answer Submitted:  February 25, 2005  8:36 am  by  GRowl   0 pts.
All Answer Wiki Contributors:  GRowl   0 pts.
To see all answers submitted to the Answer Wiki: View Answer History.