Unable to over ride a PF member

5 pts.
Tags:
AS/400 Control Language
CL
CL/400
CLRPFM
Physical File
RPG
RPG/400
RPGLE
Hi, I made a cl program and in it I over ride a pf member, clrpfm then call my rpgle program. I can't write on my member but instead it writes on the primary member and reads it. seems the member that is used is the the primary member and not the member that I over rides.

Answer Wiki

Thanks. We'll let you know when a new response is added.

Hi,

Do you use a different activation group for your rpgle? Do you have share *YES specified?

Regards,

Martin Gilbert.

Discuss This Question: 2  Replies

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.
  • philpl1jb
    Show us the Over Ride command and the cl to the call of the RPG program Phil
    53,890 pointsBadges:
    report
  • LBurkett99
    If this is a CLLE program (instead of CLP), try adding the OVRSCOPE(*CALLLVL) parameter to you OVRDBF command
    830 pointsBadges:
    report