 




<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IT Answers &#187; Synon/Cool 2E</title>
	<atom:link href="http://itknowledgeexchange.techtarget.com/itanswers/tag/synoncool-2e/feed/" rel="self" type="application/rss+xml" />
	<link>http://itknowledgeexchange.techtarget.com/itanswers</link>
	<description></description>
	<lastBuildDate>Wed, 22 May 2013 05:09:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>Are there any Synon experts out there? (20 plus years)</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/are-there-any-synon-experts-out-there-20-plus-years/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/are-there-any-synon-experts-out-there-20-plus-years/#comments</comments>
		<pubDate>Thu, 27 Oct 2011 19:46:32 +0000</pubDate>
		<dc:creator>Trbeesley</dc:creator>
				<category><![CDATA[RPG]]></category>
		<category><![CDATA[RPG ILE]]></category>
		<category><![CDATA[RPG IV]]></category>
		<category><![CDATA[RPG Language Support]]></category>
		<category><![CDATA[RPG/400]]></category>
		<category><![CDATA[RPGILE]]></category>
		<category><![CDATA[RPGLE]]></category>
		<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon 2E]]></category>
		<category><![CDATA[Synon/2E]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Experienced, 20 years plus, synon developers have probably forgotten more about synon than the new generation (yes there are young people learning synon) will ever know.   Does any of those experts remember the phantom + sign on subfile displays when there were no more records to display?  If so, what is the solution to [...]]]></description>
				<content:encoded><![CDATA[<p>Experienced, 20 years plus, synon developers have probably forgotten more about synon than the new generation (yes there are young people learning synon) will ever know. <br/><br/>  <br/><br/> Does any of those experts remember the phantom + sign on subfile displays when there were no more records to display?  If so, what is the solution to preventing it? <br/><br/></p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/are-there-any-synon-experts-out-there-20-plus-years/feed/</wfw:commentRss>
		<slash:comments>8</slash:comments>
		</item>
		<item>
		<title>How to prevent + sign or &#8216;More&#8217; from displaying on Synon generated display file when no records left to load?</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/subfile-display-plus-sign/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/subfile-display-plus-sign/#comments</comments>
		<pubDate>Tue, 25 Oct 2011 22:09:46 +0000</pubDate>
		<dc:creator>Trbeesley</dc:creator>
				<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon 2E]]></category>
		<category><![CDATA[Synon/2E]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[New Answer by]]></description>
				<content:encoded><![CDATA[New Answer by ]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/subfile-display-plus-sign/feed/</wfw:commentRss>
		<slash:comments>17</slash:comments>
		</item>
		<item>
		<title>Enter in to synon main menu from AS/400</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/enter-in-to-synon-main-menu-from-as400/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/enter-in-to-synon-main-menu-from-as400/#comments</comments>
		<pubDate>Sat, 08 May 2010 10:16:14 +0000</pubDate>
		<dc:creator>Kalyan3009</dc:creator>
				<category><![CDATA[AS/400]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Hi can any body tell how can i enter into synon from as/400 command line.When i entered ystry2 it showing the message the command in not present in *libl.I dont know the library that synon uses in my company as/400 server. How can i find the Library name of Synon model.]]></description>
				<content:encoded><![CDATA[<p>Hi can any body tell how can i enter into synon from as/400 command line.When i entered ystry2 it showing the message the command in not present in *libl.I dont know the library that synon uses in my company as/400 server. How can i find the Library name of Synon model.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/enter-in-to-synon-main-menu-from-as400/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Synon &#8211; Maximum OR conditions in CASE Statement</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/synon-maximum-or-conditions-in-case-statement/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/synon-maximum-or-conditions-in-case-statement/#comments</comments>
		<pubDate>Tue, 17 Nov 2009 10:28:00 +0000</pubDate>
		<dc:creator>Maheshero</dc:creator>
				<category><![CDATA[OS/400]]></category>
		<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Hi, My Synon program doesnt allows me to add more than 10 OR Conditions in one CASE Statement. C1 OR C2 OR  C3 OR C4 OR C5 OR C6 OR C7 OR C8 OR C9 OR C10 OR C11 OR C12 OR C13. when given like above, it only generates the source for first 10 [...]]]></description>
				<content:encoded><![CDATA[<p>Hi,<br/><br/> My Synon program doesnt allows me to add more than 10 OR Conditions in one CASE Statement.<br/><br/> C1 OR C2 OR  C3 OR C4 OR C5 OR C6 OR C7 OR C8 OR C9 OR C10 OR C11 OR C12 OR C13.<br/><br/> when given like above, it only generates the source for first 10 conditions. Remaining are ignore and even no error messages while generating the source or compiling the program.<br/><br/> Is there any setup needs to be done or it was synon&#8217;s functionality to provide only 10 conditions in one single case statement.<br/><br/>  <br/><br/>  <br/><br/></p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/synon-maximum-or-conditions-in-case-statement/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>SYNON 2E (COOL 2E)</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/synon-2e-cool-2e-2/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/synon-2e-cool-2e-2/#comments</comments>
		<pubDate>Tue, 14 Jul 2009 13:17:35 +0000</pubDate>
		<dc:creator>MAGIC</dc:creator>
				<category><![CDATA[AS/400]]></category>
		<category><![CDATA[Synon/2E]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Can anybody explain me about the Sharing concept in Synon&#8230;]]></description>
				<content:encoded><![CDATA[<p>Can anybody explain me about the Sharing concept in Synon&#8230;</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/synon-2e-cool-2e-2/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>Crib sheet for F keys in Synon screen designer?</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/crib-sheet-for-f-keys-in-synon-screen-designer/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/crib-sheet-for-f-keys-in-synon-screen-designer/#comments</comments>
		<pubDate>Thu, 14 May 2009 11:38:31 +0000</pubDate>
		<dc:creator>MMTechnical</dc:creator>
				<category><![CDATA[5250 session]]></category>
		<category><![CDATA[iSeries]]></category>
		<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon/2E]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Does anyone have/know where I can get a crib sheet or instructions I can skim through for the Synon screen designer tool? I had one, but seem to have lost it. I only use this very occasionally, so my memory can be a little patchy&#8230;]]></description>
				<content:encoded><![CDATA[<p>Does anyone have/know where I can get a crib sheet or instructions I can skim through for the Synon screen designer tool? I had one, but seem to have lost it. I only use this very occasionally, so my memory can be a little patchy&#8230;</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/crib-sheet-for-f-keys-in-synon-screen-designer/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Security for Synon library lists?</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/security-for-synon-library-lists/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/security-for-synon-library-lists/#comments</comments>
		<pubDate>Wed, 13 May 2009 11:12:04 +0000</pubDate>
		<dc:creator>MMTechnical</dc:creator>
				<category><![CDATA[iSeries]]></category>
		<category><![CDATA[iSeries security]]></category>
		<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon/2E]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I am having some problems locking down the library lists available to my developers. I&#8217;m sure previously, if they attempted to change their library list, using the synon library lists previously setup, and they were not authorised to one of the libraries in that list, it would fail. For some reason it doesn&#8217;t fail now [...]]]></description>
				<content:encoded><![CDATA[<p>I am having some problems locking down the library lists available to my developers. I&#8217;m sure previously, if they attempted to change their library list, using the synon library lists previously setup, and they were not authorised to one of the libraries in that list, it would fail. For some reason it doesn&#8217;t fail now and we get swamped with authority errors because they have &#8220;live&#8221; objects in a developers job library list. </p>
<p>I have looked at the lists themselves and there doesn&#8217;t seem to be a way of securing them from there. There has been no authority changes to the libraries themselves and I have been through and checked them.</p>
<p>Any help greatly appreciated!</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/security-for-synon-library-lists/feed/</wfw:commentRss>
		<slash:comments>4</slash:comments>
		</item>
		<item>
		<title>Certification sites for Synon?</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/certifications-2/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/certifications-2/#comments</comments>
		<pubDate>Wed, 13 May 2009 06:13:11 +0000</pubDate>
		<dc:creator>Jammypune</dc:creator>
				<category><![CDATA[AS/400 certification]]></category>
		<category><![CDATA[Certifications]]></category>
		<category><![CDATA[DB2/400]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Hello, Please can anyone suggest some good certification sites or courses for Synon or DB2 400. Except the ones from IBM. Synon is more broadly needed!!]]></description>
				<content:encoded><![CDATA[<p>Hello,</p>
<p>Please can anyone suggest some good certification sites or courses for Synon or DB2 400. Except the ones from IBM. Synon is more broadly needed!!</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/certifications-2/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AS/400, Cool/2e</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/as400-cool2e/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/as400-cool2e/#comments</comments>
		<pubDate>Sat, 25 Apr 2009 10:40:02 +0000</pubDate>
		<dc:creator>Reenasudarshan</dc:creator>
				<category><![CDATA[AS/400 Synon]]></category>
		<category><![CDATA[Cool:2e]]></category>
		<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[What is the difference between Cool:Plex and Cool:2E]]></description>
				<content:encoded><![CDATA[<p>What is the difference between Cool:Plex and Cool:2E</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/as400-cool2e/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>CPF0006 during SBMJOB (COOL 2E generated code)</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/cpf0006-during-sbmjob-cool-2e-generated-code/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/cpf0006-during-sbmjob-cool-2e-generated-code/#comments</comments>
		<pubDate>Tue, 10 Feb 2009 05:11:43 +0000</pubDate>
		<dc:creator>Gokulvirtual</dc:creator>
				<category><![CDATA[COBOL]]></category>
		<category><![CDATA[COBOL/400]]></category>
		<category><![CDATA[CPF0006]]></category>
		<category><![CDATA[SBMJOB]]></category>
		<category><![CDATA[Synon]]></category>
		<category><![CDATA[Synon/Cool 2E]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I have used SBMJOB in the COOL 2E SYNON code (Generating COBOL source). During runtime, the fucntion crashes with CPF0006 message when trying to submit the program through Y2CMEXC. Is it the error caused by the Y2BLSJR command through which the parameters for the SBMJOB is set? Parameter 1 MOVE P1XYZ TO WSSTR MOVE &#8216;A&#8217; [...]]]></description>
				<content:encoded><![CDATA[<p>I have used SBMJOB in the COOL 2E SYNON code (Generating COBOL source).<br />
During runtime, the fucntion crashes with CPF0006 message when trying to submit the program through Y2CMEXC. </p>
<p>Is it the error caused by the Y2BLSJR command through which the parameters for the SBMJOB is set? </p>
<p>Parameter 1<br />
MOVE P1XYZ TO WSSTR<br />
MOVE &#8216;A&#8217; TO WSTYP<br />
MOVE 2 TO WSLEN<br />
MOVE 0 TO WSDEC<br />
CALL &#8216;Y2BLSJR&#8217; USING<br />
  W0RTN<br />
  WSSTR<br />
  WSTYP<br />
  WSLEN<br />
  WSDEC<br />
  WSRQS<br />
END-CALL             </p>
<p>Parameter 2<br />
MOVE P1ABC TO WSPAK<br />
MOVE WSPAK TO WSSTR<br />
MOVE &#8216;B&#8217; TO WSTYP<br />
MOVE 4 TO WSLEN<br />
MOVE 0 TO WSDEC<br />
CALL &#8216;Y2BLSJR&#8217; USING<br />
  W0RTN<br />
  WSSTR<br />
  WSTYP<br />
  WSLEN<br />
  WSRQS<br />
 END-CALL </p>
<p>The parameters are defined as FLD in Cool 2E SYSNON code. Cool 2E version 1135</p>
<p>Please clarify my doubt</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/cpf0006-during-sbmjob-cool-2e-generated-code/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Page Caching using memcached
Database Caching 3/26 queries in 0.041 seconds using memcached
Object Caching 946/1086 objects using memcached

Served from: itknowledgeexchange.techtarget.com @ 2013-05-22 06:52:54 -->