1
  • SAVSYS Message Log

    We ran a SAVSYS by doing Go SAVE and then option 22. A message needing a reply came up and was replied to. We thought the message would be saved and appear in the log but we can't find it now. Is there a separate log for a SAVSYS? If so, where can I find it?

    LLBrown5 pointsBadges:
  • Transfering (save/restore) job scheduler from one AS400 to another

    Other than a SAVSYS, which I believe saves the native job scheduler which can subsequently be restored, is there a way to simply save and then restore (on a different AS400) all the entries on the job scheduler on their own?

    Zack265 pointsBadges:
  • Loading from one I515 to another

    We have 2 I515 systems. One is fully configured and in use. The second is as IBM shipped it with the basic operating system etc. Can I use my SAVSYS and regular saves to load the second system??? There could be a twist in that the second system may have a different primary language.

    JaneS485 pointsBadges:
  • How do I NOT save a file

    Once a month we run an Entire System Save. For reasons that are hard to explain I would like to Not save several files when we do a System Save. IBM has given me a couple of options. One being to FTP the file to a server, delete it, run the save then FTP file back to the library. The second being...

    Rjrohwer25 pointsBadges:
  • AS/400 V5R4 – Trying to run a system save in nightly routines.

    AS/400 V5R4 - Trying to run a system save in nightly routines. ENDSYS *ALL submitted to QCTL with parameter BCHTIMLMT set for enough time for SAVSYS to run. System does go into restricted state but then Subsystem QCTL starts straight after (2 mins). How do I keep system in a resricted state? What...

    ITDavid140 pointsBadges:
  • SAVSYS runs for half and an hour

    Recently, We executed SAVSYS in restricted state. I know that SAVSYS usually runs for about 10 minutes. But, at that time , SAVSYS had run half and an hour. I don't know why SAVSYS runs much time. I know that SAVSYS save LIC, SAVSECDTA,SAVCFG. But I have know idea about what is bad. I don't know...

    Kagacchi35 pointsBadges:
  • Increasingly lengthy SAVSYS times

    Our time required for SAVSYS is growing, and we have not had much success with IBM on getting answers on why and how to fix. We orginally thought the bulk of the time was with the SAVSECDTA, and then discovered user profiles owning large numbers of objects - most being scanned images. However, the...

    Drhankins15 pointsBadges:
  • SAVSYS vs Daily Backups

    My question is about the AS/400 and SAVSYS. Is it true that a daily backup process backs-up everything that has changed since the last SAVSYS? I’m being told that all changes (including data, programs and patches) are backed up as part of the daily backup. They also tell me that the daily backup...

    Pepper5 pointsBadges:
  • ending a savsys if tape is bad

    our tape is not advancing in the backup operation - how to end the job? so we can restart the backup with a new tape?

    Dsterba5 pointsBadges:
  • Do we need to run SAVSYS every 6 months ?

    With the new iSeries box.I wonder do we need to run SAVSYS from time to time ? Thanks

    As400i52010 pointsBadges:
  • SRC C167280A/C1F7280A

    Hi, We are at a DR test site and on the first stage of IPL'ing from the SAVSYS tape, the IPL is still progressing with the SRC - C167280A/C1F7280A. Now are these SRC's quite normal?

    harisudhan211,005 pointsBadges:
1

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to: