 




<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IT Answers &#187; SAVLIB</title>
	<atom:link href="http://itknowledgeexchange.techtarget.com/itanswers/tag/savlib/feed/" rel="self" type="application/rss+xml" />
	<link>http://itknowledgeexchange.techtarget.com/itanswers</link>
	<description></description>
	<lastBuildDate>Sat, 18 May 2013 21:33:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>Upgrade/migrate from 720 v4r5 to i5 520 v5r4</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/upgrademigrate-from-720-v4r5-to-i5-520-v5r4/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/upgrademigrate-from-720-v4r5-to-i5-520-v5r4/#comments</comments>
		<pubDate>Tue, 07 May 2013 15:25:41 +0000</pubDate>
		<dc:creator>Andrewsdad</dc:creator>
				<category><![CDATA[AS/400]]></category>
		<category><![CDATA[iSeries]]></category>
		<category><![CDATA[RSTLIB]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false">http://itknowledgeexchange.techtarget.com/itanswers/upgrademigrate-from-720-v4r5-to-i5-520-v5r4/</guid>
		<description><![CDATA[New Discussion Post by TomLiotta]]></description>
				<content:encoded><![CDATA[New Discussion Post by TomLiotta]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/upgrademigrate-from-720-v4r5-to-i5-520-v5r4/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>SAVF: Backing up all user libraries</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/savf/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/savf/#comments</comments>
		<pubDate>Mon, 19 Sep 2011 12:07:55 +0000</pubDate>
		<dc:creator>Rajasekhar15</dc:creator>
				<category><![CDATA[AS/400 Library]]></category>
		<category><![CDATA[SAVF]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[i tried to backup all our user libraries  using savf, but i can&#8217;t able to give more than one library.how could i sav all the lib? ex: i have lib&#8217;s user1lib &#124; user10lib &#124; user16lib i have to sav all the obj init?]]></description>
				<content:encoded><![CDATA[<p>i tried to backup all our user libraries  using savf, but i can&#8217;t able to give more than one library.how could i sav all the lib?</p>
<div></div>
<div>ex: i have lib&#8217;s</div>
<div></div>
<div>user1lib</div>
<div>|</div>
<div>user10lib</div>
<div>|</div>
<div>user16lib</div>
<div></div>
<div>i have to sav all the obj init?</div>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/savf/feed/</wfw:commentRss>
		<slash:comments>12</slash:comments>
		</item>
		<item>
		<title>Errors on savlib command</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/errors-on-savlib-command/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/errors-on-savlib-command/#comments</comments>
		<pubDate>Thu, 28 Jul 2011 19:34:35 +0000</pubDate>
		<dc:creator>Hawgbear</dc:creator>
				<category><![CDATA[AS/400 backup]]></category>
		<category><![CDATA[AS/400 commands]]></category>
		<category><![CDATA[SAV commands]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[When I do a full backup getting error cpf3837 during sav command , then requires a C or G to continue how Do i fix]]></description>
				<content:encoded><![CDATA[<p>When I do a full backup getting error cpf3837 during sav command , then requires a C or G to continue how Do i fix</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/errors-on-savlib-command/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>Executing the savlib command twice</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/executing-the-savlib-command-twice/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/executing-the-savlib-command-twice/#comments</comments>
		<pubDate>Tue, 08 Feb 2011 14:48:45 +0000</pubDate>
		<dc:creator>AS400PCFileTransfer16</dc:creator>
				<category><![CDATA[Automated Tape Library]]></category>
		<category><![CDATA[iSeries]]></category>
		<category><![CDATA[SAVLIB]]></category>
		<category><![CDATA[Tape Backups]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[It has been propose to have a hot tape backup in our tape library in a reserved slot. we have 22 available slots the 23rd is reserved for the cleaning cartridge. Slots 1 &#8211; 7 are used daily. What they want is to execute a second save library command to let say slot 21. This [...]]]></description>
				<content:encoded><![CDATA[<p>It has been propose to have a hot tape backup in our tape library in a reserved slot. we have 22 available slots the 23rd is reserved for the cleaning cartridge. Slots 1 &#8211; 7 are used daily. What they want is to execute a second save library command to let say slot 21. This would be used every night. This is so we could have the current backup in house. Normally are daily backup is taken to a secure site. Any opinions will be welcome on this process.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/executing-the-savlib-command-twice/feed/</wfw:commentRss>
		<slash:comments>12</slash:comments>
		</item>
		<item>
		<title>Run AS/400 backup based on objects count</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/run-backup-based-on-objects-count/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/run-backup-based-on-objects-count/#comments</comments>
		<pubDate>Sun, 09 Jan 2011 07:14:44 +0000</pubDate>
		<dc:creator>22917</dc:creator>
				<category><![CDATA[AS/400 backup]]></category>
		<category><![CDATA[AS/400 objects]]></category>
		<category><![CDATA[SAVF]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I have a requiremet that I need to run a savlib command if the particular library has more than 100 objects.[Br style=&#8221;padding: 0px; margin: 0px;&#8221; />How this can be done?[Br style=&#8221;padding: 0px; margin: 0px;&#8221; />[Br style=&#8221;padding: 0px; margin: 0px;&#8221; />Help me out with this! First i have to create a SAVF. how to create a [...]]]></description>
				<content:encoded><![CDATA[<p><b>I have a requiremet that I need to run a savlib command if the particular library has more than 100 objects.[Br style=&#8221;padding: 0px; margin: 0px;&#8221; />How this can be done?[Br style=&#8221;padding: 0px; margin: 0px;&#8221; />[Br style=&#8221;padding: 0px; margin: 0px;&#8221; />Help me out with this!</b></p>
<div><b><br />
</b></div>
<div><b>First i have to create a SAVF.</b></div>
<div><b>how to create a savf.</b></div>
<div><b>and also </b></div>
<div><b>i need the code to do the above condition&#8230;.</b></div>
<div><b><br />
</b></div>
<div><b>Please&#8230;</b></div>
<div><b>[Br style="padding: 0px; margin: 0px;" /></b>
</div>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/run-backup-based-on-objects-count/feed/</wfw:commentRss>
		<slash:comments>5</slash:comments>
		</item>
		<item>
		<title>Saving AS/400 Libraries</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/saving-libraries/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/saving-libraries/#comments</comments>
		<pubDate>Thu, 08 Jul 2010 21:29:02 +0000</pubDate>
		<dc:creator>qmaster</dc:creator>
				<category><![CDATA[AS/400 backup]]></category>
		<category><![CDATA[BRMS Backup]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[We  want backup libraries which are starting with letter “A” .we have  around 100+ libraries’ and I don’t want to mention all 100+ libraries. How can I backup those libraries which start with letter ‘A’? either from BRMS OR OS/400 pls do the need ful AS/400]]></description>
				<content:encoded><![CDATA[<p>We  want backup libraries which are starting with letter “A” .we have  around 100+ libraries’ and I don’t want to mention all 100+ libraries. How can I backup those libraries which start with letter ‘A’?<br/><br/> either from BRMS OR OS/400<br/><br/> pls do the need ful<br/><br/> AS/400<br/><br/></p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/saving-libraries/feed/</wfw:commentRss>
		<slash:comments>7</slash:comments>
		</item>
		<item>
		<title>Phantom locks</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/phantom-locks/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/phantom-locks/#comments</comments>
		<pubDate>Fri, 28 May 2010 15:13:36 +0000</pubDate>
		<dc:creator>Splat</dc:creator>
				<category><![CDATA[AS/400]]></category>
		<category><![CDATA[iSeries]]></category>
		<category><![CDATA[OS/400]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Our nightly backups consist of a series of saves to save files, followed by a save of the save file library to tape. For the past 10 days or so the program has been receiving CPF3761 &#8211; Cannot use FILE EC#FILE in SAVELIBS. milliseconds after the SAVLIB command is issued. The second-level text reads FILE [...]]]></description>
				<content:encoded><![CDATA[<p>Our nightly backups consist of a series of saves to save files, followed by a save of the save file library to tape.<br />
For the past 10 days or so the program has been receiving <b>CPF3761 &#8211; Cannot use FILE EC#FILE in SAVELIBS.</b> milliseconds after the SAVLIB command is issued.  The second-level text reads <b>FILE EC#FILE is locked by another job, or another save or restore operation is in progress for this object or for library SAVELIBS.</b><br />
A WRKOBJLCK OBJ(SAVELIBS/EC#FILE) OBJTYPE(*FILE) OUTPUT(*PRINT) issued just prior to the SAVLIB tells me that no locks exist for the specified object.<br />
An ALCOBJ OBJ((SAVELIBS *LIB *EXCLRD)) issued just prior to the SAVLIB has no effect.<br />
The only time CPF3761 didn&#8217;t make an appearance was after I&#8217;d deleted the EC#FILE save file from the library (the program will create a save file if one doesn&#8217;t exist).<br />
Reviewing the system logs for the times in question don&#8217;t show anything that could be locking the save file.  The scheduled run time has been changed (twice) to try and avoid anything missed in the logs, to no effect.<br />
I&#8217;m running pretty low on ideas, so any suggestions would be appreciated.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/phantom-locks/feed/</wfw:commentRss>
		<slash:comments>29</slash:comments>
		</item>
		<item>
		<title>MCH3601 &#8211; Pointer not set for referenced location during backup</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/mch3601-pointer-not-set-for-location-referenced-during-backup/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/mch3601-pointer-not-set-for-location-referenced-during-backup/#comments</comments>
		<pubDate>Tue, 06 Jan 2009 03:33:24 +0000</pubDate>
		<dc:creator>DoubleL</dc:creator>
				<category><![CDATA[LPAR]]></category>
		<category><![CDATA[MCH3601]]></category>
		<category><![CDATA[RCLSTG]]></category>
		<category><![CDATA[SAVACT]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I am runing &#8211; SAVLIB LIB(*ALLUSR) SAVACT(*SYNCLIB) This is on my DEV LPAR so i was able to run RCLSTG. It did not solve the problem. Any suggestions? I am receiving it on MANY files.]]></description>
				<content:encoded><![CDATA[<p>I am runing &#8211; SAVLIB LIB(*ALLUSR) SAVACT(*SYNCLIB)  This is on my DEV LPAR so i was able to run RCLSTG. It did not solve the problem.  Any suggestions?  I am receiving it on MANY files.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/mch3601-pointer-not-set-for-location-referenced-during-backup/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>RSTLIB and Journaling</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/rstlib-and-journaling/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/rstlib-and-journaling/#comments</comments>
		<pubDate>Fri, 05 Dec 2008 16:31:06 +0000</pubDate>
		<dc:creator>wpoulin</dc:creator>
				<category><![CDATA[AS/400]]></category>
		<category><![CDATA[FTP]]></category>
		<category><![CDATA[i5]]></category>
		<category><![CDATA[iSeries]]></category>
		<category><![CDATA[RSTLIB]]></category>
		<category><![CDATA[RSTLIB Errors]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I am doing a SAVLIB of our Production Data Libraries creating SaveFiles on our Production iSeries, then thru FTP, transferring the SaveFiles to our Development iSeries, then doing RSTLIBs. During the RSTLIBs I get a CPF7085 &#8211; Journal QSQJRN already exists and CPF3756 &#8211; JRN QSQJRN not restored. It was my understanding that doing a [...]]]></description>
				<content:encoded><![CDATA[<p>I am doing a SAVLIB of our Production Data Libraries creating SaveFiles on our Production iSeries, then thru FTP, transferring the SaveFiles to our Development iSeries, then doing RSTLIBs.  During the RSTLIBs I get a CPF7085 &#8211; Journal QSQJRN already exists and CPF3756 &#8211; JRN QSQJRN not restored.<br />
It was my understanding that doing a SAVLIB then a RSTLIB to the same named library would restore the Journal, Journal Receiver, and Data Files.<br />
Am I missing something in this process ?</p>
<p>Thanks,<br />
Bill Poulin</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/rstlib-and-journaling/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SAVLIB to SAVF</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/savlib-to-savf/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/savlib-to-savf/#comments</comments>
		<pubDate>Thu, 07 Aug 2008 17:49:20 +0000</pubDate>
		<dc:creator>Chardyjr</dc:creator>
				<category><![CDATA[FTP]]></category>
		<category><![CDATA[iSeries]]></category>
		<category><![CDATA[SAVF]]></category>
		<category><![CDATA[SAVLIB]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Do I need to change any parameters when trying to savlib to a savf to FTP to another I-series to create the same environment?]]></description>
				<content:encoded><![CDATA[<p>Do I need to change any parameters when trying to savlib to a savf to FTP to another I-series to create the same environment?</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/savlib-to-savf/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Page Caching using memcached
Database Caching 3/22 queries in 0.027 seconds using memcached
Object Caching 938/1048 objects using memcached

Served from: itknowledgeexchange.techtarget.com @ 2013-05-18 22:59:34 -->