 




<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IT Answers &#187; Data Center Fire Suppression</title>
	<atom:link href="http://itknowledgeexchange.techtarget.com/itanswers/tag/data-center-fire-suppression/feed/" rel="self" type="application/rss+xml" />
	<link>http://itknowledgeexchange.techtarget.com/itanswers</link>
	<description></description>
	<lastBuildDate>Sat, 25 May 2013 15:43:48 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	
		<item>
		<title>Fire suppression system for server room</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/fire-suppression-system-for-server-room/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/fire-suppression-system-for-server-room/#comments</comments>
		<pubDate>Wed, 18 Aug 2010 14:45:53 +0000</pubDate>
		<dc:creator>Mike4117</dc:creator>
				<category><![CDATA[Data center design]]></category>
		<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[FM-200]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Can you give me a lead to someone in San Jose area that does install of Novec 1230 or FM-200 systems for very low prices mentioned on website? A figure of $2.50 per square ft is mentioned.  I have been quoted prices in area of $35.00 per square foot.  Why?]]></description>
				<content:encoded><![CDATA[<p>Can you give me a lead to someone in San Jose area that does install of Novec 1230 or FM-200 systems for very low prices mentioned on website?<br />
A figure of $2.50 per square ft is mentioned.  I have been quoted prices in area of $35.00 per square foot.  Why?</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/fire-suppression-system-for-server-room/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>in fm-200 sytem, integration test also included.</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/in-fm-200-sytem-integration-test-also-included/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/in-fm-200-sytem-integration-test-also-included/#comments</comments>
		<pubDate>Wed, 04 Aug 2010 14:57:23 +0000</pubDate>
		<dc:creator>Qatar</dc:creator>
				<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[FM-200]]></category>
		<category><![CDATA[FM-200 Fire Suppression Systems]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I want to know that its compulsary that we have to intgration test for fm-200 rooms, or we can do visual check with out  doing the integration test to say that the room is ok.]]></description>
				<content:encoded><![CDATA[<p>I want to know that its compulsary that we have to intgration test for fm-200 rooms, or we can do visual check with out  doing the integration test to say that the room is ok.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/in-fm-200-sytem-integration-test-also-included/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FM-200 FOR SERVER ROOM</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/fm-200-for-server-room/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/fm-200-for-server-room/#comments</comments>
		<pubDate>Thu, 06 May 2010 06:14:31 +0000</pubDate>
		<dc:creator>Faruk</dc:creator>
				<category><![CDATA[BS]]></category>
		<category><![CDATA[Data center design]]></category>
		<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[FM-200]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[HOW TO DO PIPE SIZING FOR FM 200 AS PER STANDARD BS/NFPA.?]]></description>
				<content:encoded><![CDATA[<p>HOW TO DO PIPE SIZING FOR FM 200 AS PER STANDARD BS/NFPA.?</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/fm-200-for-server-room/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Inergen release associated with acute hard drive failure rate. What effect causes the damage?</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/inergen-release-associated-with-acute-hard-drive-failure-rate-what-effect-causes-the-damage/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/inergen-release-associated-with-acute-hard-drive-failure-rate-what-effect-causes-the-damage/#comments</comments>
		<pubDate>Tue, 30 Mar 2010 14:54:17 +0000</pubDate>
		<dc:creator>EeektheMad</dc:creator>
				<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[Data center operations]]></category>
		<category><![CDATA[Fire suppression]]></category>
		<category><![CDATA[Server maintenance]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[New Discussion Post by]]></description>
				<content:encoded><![CDATA[New Discussion Post by ]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/inergen-release-associated-with-acute-hard-drive-failure-rate-what-effect-causes-the-damage/feed/</wfw:commentRss>
		<slash:comments>4</slash:comments>
		</item>
		<item>
		<title>Applicability and storage tanks for FM-200 (2 questions)</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/applicability-and-storage-tanks-for-fm-200-2-questions/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/applicability-and-storage-tanks-for-fm-200-2-questions/#comments</comments>
		<pubDate>Fri, 13 Nov 2009 20:18:44 +0000</pubDate>
		<dc:creator>Colosalesguy</dc:creator>
				<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[DataCenter]]></category>
		<category><![CDATA[Fire suppression]]></category>
		<category><![CDATA[FM-200]]></category>
		<category><![CDATA[Waterless Agents]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Question Edited by Michael Tidmarsh]]></description>
				<content:encoded><![CDATA[Question Edited by Michael Tidmarsh]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/applicability-and-storage-tanks-for-fm-200-2-questions/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Data center fire supression design: FM200 cylinder storage</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-supression-design-fm200-cylinder-storage/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-supression-design-fm200-cylinder-storage/#comments</comments>
		<pubDate>Mon, 27 Jul 2009 16:48:23 +0000</pubDate>
		<dc:creator>Data Center - Ask the Expert</dc:creator>
				<category><![CDATA[Data center design]]></category>
		<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[FM-200 Fire Suppression Systems]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[Could the gas suppression cylinders be installed and stored inside a building. (FM 200). Should a data center services penetration be sealed with intumescent material.]]></description>
				<content:encoded><![CDATA[<p>Could the gas suppression cylinders be installed and stored inside a building.<br />
(FM 200).</p>
<p>Should a data center services penetration be sealed with intumescent material.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-supression-design-fm200-cylinder-storage/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Data center fire supression system comparison</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-supression-system-comparison/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-supression-system-comparison/#comments</comments>
		<pubDate>Mon, 27 Jul 2009 16:44:10 +0000</pubDate>
		<dc:creator>Data Center - Ask the Expert</dc:creator>
				<category><![CDATA[Data center design]]></category>
		<category><![CDATA[Data Center Fire Suppression]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[I want to ask about the difference between FM200 &#038; NAF S125, and which one is better.]]></description>
				<content:encoded><![CDATA[<p>I want to ask about the difference between <a href="http://www2.dupont.com/FE/en_US/products/FM200.html">FM200</a> &#038;<a href="http://www.alibaba.com/product/mamirah-11619378-11010972/NAF_S_125_HFC_125_Fire_Suppression_System.html"> NAF S125</a>, and which one is better.</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-supression-system-comparison/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Data center fire suppression &#8212; what do you use?</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-suppression-what-do-you-use/</link>
		<comments>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-suppression-what-do-you-use/#comments</comments>
		<pubDate>Fri, 05 Jun 2009 21:09:59 +0000</pubDate>
		<dc:creator>JennyMack</dc:creator>
				<category><![CDATA[Data center fire prevention]]></category>
		<category><![CDATA[Data Center Fire Suppression]]></category>
		<category><![CDATA[Fire suppression]]></category>
		<category><![CDATA[Water-Based Data Center Fire Suppression]]></category>
		<category><![CDATA[Waterless Agents]]></category>

		<guid isPermaLink="false"></guid>
		<description><![CDATA[What do you use as your method of data center fire suppression? Water-based? Waterless agents? What led you to your decision?]]></description>
				<content:encoded><![CDATA[<p>What do you use as your method of data center fire suppression? Water-based? Waterless agents? What led you to your decision?</p>
<!-- wpms-network-global-inserts -->]]></content:encoded>
			<wfw:commentRss>http://itknowledgeexchange.techtarget.com/itanswers/data-center-fire-suppression-what-do-you-use/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Page Caching using memcached
Database Caching 3/16 queries in 0.023 seconds using memcached
Object Caching 782/840 objects using memcached

Served from: itknowledgeexchange.techtarget.com @ 2013-05-25 22:51:20 -->