Prefabricated data centers -- pros and cons?

I was wondering if you have heard much about the market’s acceptance of the prefabricated data center concept? What are some of the fears, concerns or obstacles for this becoming the thing of the future that many are predicting.

asked by Data Center - Ask the Expert

  235 pts.

Physical and logical security for new datacenter

Am looking for best practice recommendations for implementing both physical and logical security for a new data center build. This request for help was originally submitted to the Research Assistant on WhatIs.com.

View Answer   |  Sep 9 2008  5:18 PM GMT
Security, Physical security, Data center design
asked by ResearchAssistant

  855 pts.

Computer room leak

What additional protection can you provide above drop ceiling to prevent water damage to equipment?

View Answer   |  Aug 14 2008  5:24 PM GMT
Data center design
asked by Gabby

  5 pts.

Variable Refrigerant Volume ( VRV)

Is it a right solotion to implement VRV at data center compare with APC in row air cond system ? addditonal info: the raise floor height is 30cm, the the ceiling height is around 2 feet from rack. 600 sq feet room which located with 18 high density rack.

asked by Chuah

  5 pts.

Damage caused by FM-200 Fire Supression Systems

What damage would be caused to equipment and data within a typical server room by the activation of a gas based Fire Suppression System such as the FM200 and what is the likelihood of it being inadvertently activated?

asked by Dougdon

  5 pts.

FE-25 vs FM-200 fire suppression

If I have to choose between an FE-25 based fire supression system or one using the more common FM-200 why would I choose one over the other? Which one is superior in a data center application?

asked by Dwreid

  5 pts.

Can split air conditioner be installed in data center. What humidity levels are tolerable?

Can split air conditioner be installed in data center. What humidity levels are tolerable?

asked by ITKE

  10195 pts.

Checklist for data center cable labelling

Hi, Can any one please provide the checklist for labeling the cables in the data center. Plz help me out.

View Answer   |  Jul 7 2008  11:07 AM GMT
Cabling, Data center design, Data Center
asked by Lakshmi

  5 pts.

Data Center Relocation Planning Resources

I'm looking for Data Center Relocation planning resources; books, white papers, WBS, project plans, etc. can I get some recommendations?

asked by Pain&Progress

  5 pts.

Data center facility cost formula?

Do you have a good understanding of data center build cost, ie: what % of data center costs are for the shell, fit up, mechanical, electrical, etc? Is there a simple formula or a simple % break out that is industry accepted?

asked by Data Center - Ask the Expert

  235 pts.

NFPA version used by states

I am on a team which writes data center standards for our multi-state firm. Do you know of an on-line resource to verify which version of NFPA 70 (the NEC) is presently adopted for use, by state?

Answer Question   |  May 7 2008  3:31 PM GMT
Data center design, Fire suppression
asked by Data Center - Ask the Expert

  235 pts.

Making a data center "green" -- first steps

We have a T2 data center and are attempting to “go green” and lower the energy usage in the DC. Our goal is to reach a T3 or even a T4. What would be the first steps you would suggest to take to save the most energy as soon as possible? Cover all holes in the floor? Blanking plates?

asked by Data Center - Ask the Expert

  235 pts.

status change from officebuilding to datacentre

Where can I find information ( like a step-by-step plan ) about: What steps do I have to take and with wich proces to make a building with status Office to become a building with status Datacentre

View Answer   |  Apr 29 2008  6:57 AM GMT
Data center design, Data Center
asked by HVAC

  20 pts.

Designing FM200 gas suppression system -- retrofit

A SearchDataCenter.com reader wrote in to follow up with the Ask the Expert Question Regarding Halon or FM2000. With regards to the FM200 gas suppression system, how do we go about designing the space to accomodate the gas cylinders as well as the reticulation of pipes. I understand that it...

Answer Question   |  Apr 23 2008  9:03 PM GMT
Data center design
asked by Leah Rosin

  480 pts.

Data Center Noise Levels

Has anyone taken the time to check the dB level of their data center or server room ? I am wondering if there is a cheap/easy way to determine if the dB level is high enough to worry about ear protection.

Answer Question   |  Apr 18 2008  7:49 PM GMT
Data center operations, Data center design
asked by Dedward

  5 pts.

Safety of non mattalic opital fiber cable?

How one can best protect non-metallic optical fiber cable from rodents (RATS) attack?

View Answer   |  Mar 26 2008  5:52 PM GMT
Cabling, Data center design, Optical Fiber Cable
asked by Sac0081

  5 pts.

Data Cener consulting

We are planning to build a tier IV data center and seeking professional help assist us to plan a green data center. please mail us scope of services and costs

View Answer   |  Feb 18 2008  4:29 AM GMT
Data center design, Green data center
asked by Maxx47

  5 pts.

data centre

we're running about 182servers in a single room and the room getting very noisy. wats is the best steps can be considered in this scenario.?

View Answer   |  Jan 31 2008  5:29 AM GMT
Data center design, Data Center
asked by Jayanthi

  10 pts.

Static electricity in the datacenter

im frequently hit with static while working in data centre whereby the flooring covered by carpet. im worry it may affect my servers and my health. how do i avoid from getting hit again? wats is the best solution availble to avoid or overcome this scenario?

View Answer   |  Jan 29 2008  4:48 AM GMT
Data center design, DataCenter
asked by Jayanthi

  10 pts.

What is a good server rack w/good cable management

I am looking for a good server rack with decent accessories and a must is good cable management. The best I found is Chatsworth but there M series racks are wider then 24" so it won't sit on a raised floor panel. Any opinions?

View Answer   |  Jan 9 2008  11:36 PM GMT
Data center design, Rack enclosures
asked by Kb3cgj

  580 pts.