How do I effectively cool a single rack network?

OK, the budget is practically nill for a start.  I inherited a network some time back from my former manager in IT which is composed of several servers external to the rack, 4 APC UPS1000 batteries, 2 HP rackmount g5 servers, 1 KVM, 3 switches (2 of which are rackmount, the 3rd is just housed in...

Answer Question   |  Nov 19 2009  5:42 AM GMT
server rack cooling, Data center cooling
asked by Stormchaser

  5 pts.

FNG CRAC question

I have just started working in data center and have noticed a stulz VFS-240-DAR-D with only one hot gas bypass it does have two compressors. Could any one plz tell me why this would be why. Software/Hardware used: Stuls, VFS-240-DAR-D

Answer Question   |  Sep 23 2009  11:21 PM GMT
Stulz, CRAC, Data center air conditioning units
asked by Myerspaw

  5 pts.

Server Rack best practices

When setting up a server rack is it a good idea to leave some room in between servers or can you stack them on top of eachother? Also should longer servers go below shorter servers for cooling purposes? Software/Hardware used: Server Racks

View Answer   |  Sep 23 2009  3:55 PM GMT
Servers, Data center cooling
asked by ITKE

  10270 pts.

Infrared humidifier maintenance.

Infrared humidifier maintenance. Costs to maintain infrared humidifiers is a concern add to our maintenance budget.  Hard water deposits are causing problems and constant repair bills. It has been recommended that we could use a product called "Vapure(R)" to suspend the minerals and have them...

Answer Question   |  Sep 10 2009  9:06 PM GMT
Data center cooling
asked by MikeDaigle

  30 pts.

Data Center Cooling for 60 racks

I have a computer Room almost 400 m2 and total # of Racks is 60 racks What is the best way to cool a High denisty rack (20Kw) , Software/Hardware used: Data Center cooling

asked by ITKE

  10270 pts.

Data Center Cooling suggestions

What is the best method of Data Center cooling? We currently have a 10 ton unit blowing air from above and a 5 ton unit blowing below. We spent $100,000 on these new units and duct work 3 years ago and now they are maxed out. We do use the hot and cold isle method. Since we continue to add...

View Answer   |  Aug 11 2009  3:52 PM GMT
Data center cooling, Cooling systems, Power and cooling
asked by Batman47

  505 pts.

Will a hot row facing a wall cause hot spots?

I am currently in the process of planning a new pod in my datacenter. To maximize space, my plan calls for a hot row which faces a wall. Will this cause hot spots, or will it act similarly to hot row containment, and actually improve flow of return air?

View Answer   |  Jun 16 2009  4:14 PM GMT
Data center cooling, Hot Aisle/Cold Aisle, Data Center
asked by Gary50

  5 pts.

Data center cooling solutions

What do you think is the most power-efficient data center cooling setup? What kind of setup do you implement in your data center? Are there ways you would like to improve it; how?

asked by JennyMack

  3310 pts.

Damage to Data Center Equipment due to hard shutdown after power failure

We experienced hard shutdown of all our data center equipment after utility power interruption and inability of our CRAC units to properly cool the space due to problems with cooling tower. Server room heat reached around 110 degrees causing all equipment to go into a hard shutdown. It tool f hours...

asked by MG7

  5 pts.

Maximum Operating Temperature Of iSeries / P Series Servers

I work in a Data Center with a raised floor. There is a 10 ton unit that blows air from the ceiling and a 5 ton unit that only blows the air under the floor. For a backup unitl, we had an 5 ton unit that blows air from the ceiling, but that unit broke and facilities refuses to repair it...

View Answer   |  Apr 14 2009  4:24 PM GMT
Data center cooling, Raised floors, iSeries data center
asked by Batman47

  505 pts.

Chilled water loop temp

For those using chilled water, when people talk about the loop temp are you refering to the temp of the water coming back to the chiller (return) or the temp of the water leaving the chiller (supply)? I have a chiller that seems to only monitor the return temp and bring on compressors based on...

asked by TimWard

  15 pts.

Cold Aisle Containment-what do you think its for?

Is it for Hot spot cooling only? or Overheating in general? or Energy saver?

View Answer   |  Jan 13 2009  4:04 PM GMT
Data center cooling, Hot Aisle/Cold Aisle
asked by CoolDataCentre18

  10 pts.

Cooling requirements for a data center with blade servers

We are planning a data center and was wondering if anyone could help with the amount of cooling we will need. We will have 100 blade servers in the data center along with other equipment We will have a raised floor as well.

View Answer   |  Dec 16 2008  4:52 PM GMT
Blade servers, Data center cooling, Data center planning
asked by ITKE

  10270 pts.

High humidity in the Data Center. Any advice?

We are having an issue with humidity levels of 65% in our Data Center. I know we should be below 55% but I was wondering if our level will really hurt the equipment. Do i need to replace my overhead coolers or can I live with this? Thanks

asked by ITKE

  10270 pts.

Reporting Cooling in BTU vs KW or CFM

Is there a standard practice in reporting BTU vs KW or CFM?

View Answer   |  Sep 25 2008  2:15 PM GMT
Data center cooling, BTU, KW
asked by ITKE

  10270 pts.

How to improve cooling efficiency of server rooms without cold-aisle/hot-aisle arrangement?

Hi, I was given server rooms where server racks are placed front-to-back without cold aisle and hot aisle. The racks are of mixed brands. I approached our APC rep and was advised to change the racks to APC racks and install back rack doors with exhaust fans as such add-ons are only meant for APC...

View Answer   |  Sep 21 2008  3:02 AM GMT
Data center design, Data center cooling, APC
asked by KaiBeng66

  5 pts.

Dealing with 30 kW heat load blade server

How do you deal with a 30 kW heat load blade server?

asked by Data Center - Ask the Expert

  235 pts.

Variable Refrigerant Volume ( VRV)

Is it a right solotion to implement VRV at data center compare with APC in row air cond system ? addditonal info: the raise floor height is 30cm, the the ceiling height is around 2 feet from rack. 600 sq feet room which located with 18 high density rack.

asked by Chuah

  5 pts.

Can split air conditioner be installed in data center. What humidity levels are tolerable?

Can split air conditioner be installed in data center. What humidity levels are tolerable?

asked by ITKE

  10270 pts.

How effective are liquid-based coolant systems in processor cooling?

I've never had the chance to work with one yet; approx. by how much percent do liquid cooling systems speed up processors? Are they worth the trouble of installation? Are there more effective and/or feasible methods of cooling available?

View Answer   |  Jul 11 2008  10:50 PM GMT
Cooling, Data center cooling
asked by Petros

  10 pts.