  • Monitor others AS/400 display stations from my workstation

    Hi, I want to monitor other active users workstations from my workstation. Display their screen on my workstation once at time. Can I do this? Please help. Thanks Chris

    Krisha5 pointsBadges:
  • Any mechanism to kill AS/400 job when RF gun is disconnected

    Hello, When a RF gun/device which is connected to a AS/400 workstation suddenly goes down due to poor RF signals in specific area, is there any way to immediately kill the AS/400 session. Currently,when the RF signal drops, the Session remains active retaining the record level locks and hence...

    Eternal30 pointsBadges:
  • FTP w/CL-Command Transfer from PF

    I need to copy a PF containing FTP commands in QCLSRC after the PF has been updated with correct file name. When I CPY using *CVTSRC, it adds SEQ# field, which causes the FTP Input file to not issue the commands correctly. How can I copy a PF into QCLSRC without adding the additional fields? (Only...

    Lsivabe85 pointsBadges:
  • as400 wrkstation

    so how many wrkstation(QPADEV000..) can be created by its own in a single AS400 server?

    Rajasekhar151,395 pointsBadges:
  • AS/400 EndJob Issue

    Hi I have been working on my as/400 session but suddenly it was ended by some remote user. How can I identify which user has ended my session remotely? Thanks, Vivek

    VivekSharma120 pointsBadges:
  • READC is activating even when no records in subfile have been changed?

    READC is activating even when no records in subfile have been changed?

    Usf210020 pointsBadges:
  • Setting permanent AS/400 IDs

    can we set workstation ids so that they are not assigned every time we sign on by the the as 400 system

    Rossdpc5 pointsBadges:
  • How to communicate with AS/400 server from Windows PC

    I have an old AS/400 server running OS/400 V3R7. I was earlier able to connect with it through Windows PC using NS Router. This AS/400 server was not being used for quite some time. Now when IPL was done and tried to connect the PC through NS Router, connection could not be made. However,...

    Sk1025 pointsBadges:
  • QCTL

    We have a 9402 model system which not connected with any workstation. Unfortunately it was disabled(hanged). screen has been locked. How can i enable qctl. and how to bring back my system into normal mode? Urgent and important Pls? ThanksIn Advace?

    qmaster1,675 pointsBadges:
  • AS400 admin/analyst

    Hi, Could anyone tell me how can I see that my workstation is attached with which LINE.I can see the controller which my workstation is attached to, but cant see the line to which this controller is attached.Please advise.  

    Herbina325 pointsBadges:
  • How to fix problem of AS/400 Workstation locking up after pressing enter ?

    When a user presses "Enter" the AS/400 session locks up sporadically. The "X SYSTEM" appears on the status line like it is locked but WRKACTJOB doesn’t show any locks or even the program processing any files. The only way to free it is by pressing "Shift & Esc", then return to the session. We are...

    Cardpunch6750 pointsBadges:
  • AS/400 Workstation error 22

    I have written expanded subfile program and display records correctly when i select one record based in the from field it is showing correctly then when i press page up it is not displaying anything and even pressing page down displaying anything. I am geeting WORKSTATION ERROR 22,23 AND 41. can...

    Karunakar5 pointsBadges:
1

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to:

To follow this tag...

There was an error processing your information. Please try again later.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Thanks! We'll email you when relevant content is added and updated.

Following