AS/400 FTP error- TCP3D2C Secure connection error, return code -24
I am trying to FTP from Backup AS/400 box to our Production AS/400 box or visa versa and I get the following error when trying to transfer a file of any significant size(larger than 1Kb): Software/Hardware used: AS/400, AS/400 FTP
I am trying to FTP from Backup AS/400 box to our Production AS/400 box or visa versa and I get the following error when trying to transfer a file of any significant size(larger than 1Kb): Software/Hardware used: AS/400, AS/400 FTP
AS 400 software problem
Received the following in wrkprb should I contact IBM Problem message ID . . . . . . . : CPI93B9 Severity . . . . . . . . . . . . : None Problem...
Received the following in wrkprb should I contact IBM Problem message ID . . . . . . . : CPI93B9 Severity . . . . . . . . . . . . : None Problem...
Journaling a file
Hi, I recieve the following error when i journal a file Damage prevents object from being journaled. Cause . . . . . : A damaged object previously journaled to this journal prevents journaling from being started for object in library type *QDDS. If the object is an...
Hi, I recieve the following error when i journal a file Damage prevents object from being journaled. Cause . . . . . : A damaged object previously journaled to this journal prevents journaling from being started for object in library type *QDDS. If the object is an...
AS/400 profile error
My profile is created few days back and whenever i login i am getting this message: [strong]Message ID . . . . . . : CPA0701 Severity . . . . . . . : 99 Message type . . . . . : ...
My profile is created few days back and whenever i login i am getting this message: [strong]Message ID . . . . . . : CPA0701 Severity . . . . . . . : 99 Message type . . . . . : ...
CPYTOIMPF data corruption
CPYTOIMPF on V5R4 with latest PTF's adds invalid data to the created CSV file for some blank fields in the PF. Is this a Bug? Software/Hardware used: AS/400 V5R4
CPYTOIMPF on V5R4 with latest PTF's adds invalid data to the created CSV file for some blank fields in the PF. Is this a Bug? Software/Hardware used: AS/400 V5R4
Trigger program written in RPGLE
I have a trigger program that have 3 files declared in F-Specs (no UsrOpn keyword). Everytime it ends, it sets the LR indicator on. Does the trigger program slow down processing when the trigger file is updated in a batch program? Should I remove the code that turns on the LR indicator? ...
I have a trigger program that have 3 files declared in F-Specs (no UsrOpn keyword). Everytime it ends, it sets the LR indicator on. Does the trigger program slow down processing when the trigger file is updated in a batch program? Should I remove the code that turns on the LR indicator? ...
Message: Call to controller QESCTL on line QESLINE failed. Time-out
Does this mean the reset of the ECS Modem would solve the issue? What exactly does this mean? Thanks Software/Hardware used: software
Does this mean the reset of the ECS Modem would solve the issue? What exactly does this mean? Thanks Software/Hardware used: software
Error message CPF0CBF
I received the following error message and haven't been able to find any information on it. Has anyone seen this before? Message ID . . . . . . : CPF0CBF Severity . . . . . . . : 20 Message type . . . . . : Escape Date sent . . . . . . : 08/12/09 Time sent . . . . . . : 11:45:43 Message . . . . :...
I received the following error message and haven't been able to find any information on it. Has anyone seen this before? Message ID . . . . . . : CPF0CBF Severity . . . . . . . : 20 Message type . . . . . : Escape Date sent . . . . . . : 08/12/09 Time sent . . . . . . : 11:45:43 Message . . . . :...
What is and Why am I getting a MCH1202 error message on a field compare statement?
From an externally define file I bring in an S9(7) comp-3 value that is a date. In the program I call the date function to get the current date. Move it to a S9(7) comp-3 field and then compare them to be equal. EVALUATE TRUE WHEN PACKED-DATE = DHIVNB do... Bang I get hit with the MCH1202 error...
From an externally define file I bring in an S9(7) comp-3 value that is a date. In the program I call the date function to get the current date. Move it to a S9(7) comp-3 field and then compare them to be equal. EVALUATE TRUE WHEN PACKED-DATE = DHIVNB do... Bang I get hit with the MCH1202 error...
CPYTOIMPF
i am new to as400 and i wanted to transfer file from as400 to pc using CPYTOIPMF as per advised here. BUt i am receiving an error File system error occurred. Error number 3025. whats wrong? thanks
i am new to as400 and i wanted to transfer file from as400 to pc using CPYTOIPMF as per advised here. BUt i am receiving an error File system error occurred. Error number 3025. whats wrong? thanks
iSeries Asynchronous Socket Error 10053
I use software called RPGsp on my XP professional PC to write web pages that uses our information on the I Series main frame, that is using version 5.4. It uses a FTP connection on the I Series to move the data. Every thing works fine in the morning but after 1:00 p.m. I start getting the message,...
View Answer
| Jul 31 2009 3:48 PM GMT
iSeries error messages, AS/400 error messages, Asynchronous Socket Error 10053
I use software called RPGsp on my XP professional PC to write web pages that uses our information on the I Series main frame, that is using version 5.4. It uses a FTP connection on the I Series to move the data. Every thing works fine in the morning but after 1:00 p.m. I start getting the message,...
iSeries error messages, AS/400 error messages, Asynchronous Socket Error 10053
AS/400 Display program error
I guess I should have been more specific. How can I tell if a user had an interactive display program message when they do not tell you? For example, they received a CPF4131 and just put "C's" through the entire message.
I guess I should have been more specific. How can I tell if a user had an interactive display program message when they do not tell you? For example, they received a CPF4131 and just put "C's" through the entire message.
AS/400 Workstation error 22
I have written expanded subfile program and display records correctly when i select one record based in the from field it is showing correctly then when i press page up it is not displaying anything and even pressing page down displaying anything. I am geeting WORKSTATION ERROR 22,23 AND 41. can...
I have written expanded subfile program and display records correctly when i select one record based in the from field it is showing correctly then when i press page up it is not displaying anything and even pressing page down displaying anything. I am geeting WORKSTATION ERROR 22,23 AND 41. can...
AS/400 virtual printer error - Device XXXX configuration not valid. Reason code 2301.
This virtual printer device has been working for months, but now it just stopped. Any advice?
This virtual printer device has been working for months, but now it just stopped. Any advice?
Problems whislt iSeries LIC recovery
Hi, We are trying to recover our DR machine its 825 and i550, when trying to boot from the SAVSYS tape we recieve the following errors i550 - B167 4609 825 - B200 300 Not sure if they are related to LIC program corrupt on the tape or something else as am not able to find it on the web as well?...
Hi, We are trying to recover our DR machine its 825 and i550, when trying to boot from the SAVSYS tape we recieve the following errors i550 - B167 4609 825 - B200 300 Not sure if they are related to LIC program corrupt on the tape or something else as am not able to find it on the web as well?...
AS/400 model 820 has a msg
okon the panel while the machine isoff 10111520 fn 97P4024 and there is an yello error on the panel after i IPL'd the log showed CPP0109 Detect ac lost andthere is a clicking sound from the back the machine is working but complaining on power supply hasanyone replaced power supply ? whats is...
okon the panel while the machine isoff 10111520 fn 97P4024 and there is an yello error on the panel after i IPL'd the log showed CPP0109 Detect ac lost andthere is a clicking sound from the back the machine is working but complaining on power supply hasanyone replaced power supply ? whats is...
CPYTOSTMP
I'm copying to a stream file and if the object exists it works. The help says if it does not exist it will create it. Here is the error msg Message ID . . . . . . : CPFA0A9 Severity . . . . . . . : 40 Message type . . . . . : Escape ...
I'm copying to a stream file and if the object exists it works. The help says if it does not exist it will create it. Here is the error msg Message ID . . . . . . : CPFA0A9 Severity . . . . . . . : 40 Message type . . . . . : Escape ...
Display "No records found" in a QMQRY
I have a QMQRY that selects data from several files using left joins. Based on my "where" clause there is a possibility that no records will be selected. In this case, I want to be able to print "NO RECORDS FOUND" on the report. I have not been able to figure out how to get that text to print on...
I have a QMQRY that selects data from several files using left joins. Based on my "where" clause there is a possibility that no records will be selected. In this case, I want to be able to print "NO RECORDS FOUND" on the report. I have not been able to figure out how to get that text to print on...
AS/400 remore access
Hi, I am having a static IP configured to the AS/400 at the client site.But I can't able to connect to the AS/400 using iseries navigator from my site locally. But when I am using the TN3270 plus as telnet mode I ma able to connect it. So please help me in resolving this issue. the error...
View Answer
| Apr 6 2009 1:34 PM GMT
AS/400 Client Access, AS/400 error messages, AS/400 remote access
Hi, I am having a static IP configured to the AS/400 at the client site.But I can't able to connect to the AS/400 using iseries navigator from my site locally. But when I am using the TN3270 plus as telnet mode I ma able to connect it. So please help me in resolving this issue. the error...
AS/400 Client Access, AS/400 error messages, AS/400 remote access
AS/400 Navigator
Hi , Can anyone tell me what is this problem when i try to click on the database tab in AS/400 navigator. Navigation: -> login to machine id->click on the machine-id->click on the database tab-> ERROR reported Function did not complete successfully. AS/400 Message ID: PWS0001 Cause...
Hi , Can anyone tell me what is this problem when i try to click on the database tab in AS/400 navigator. Navigation: -> login to machine id->click on the machine-id->click on the database tab-> ERROR reported Function did not complete successfully. AS/400 Message ID: PWS0001 Cause...


