What is the use of SFLDSPCTL, can I display a subfile without the control record format values, example is it possible to dislpay the subfile without the Main heading and the subfile fields heading which I have coded in the control record format?

Answer Wiki

Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Discuss This Question: 4  Replies

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • Splat
    You don't have to display any information on the subfile control record, but you do need it. I've never tried not making use of SFLDSPCTL, but the documentation indicates it could be done - certainly you can use an option indicator on it.
    6,995 pointsBadges:
    report
  • philpl1jb
    No, at least I've never seen this but you can Display the control reocrd without the subfile. That's one way to deal with the no records found case or the case where you want the user to enter the first search value in the "Header" area before you display reocrds. Generally both display commands are off when the SBFCLR is on. Phil.
    49,720 pointsBadges:
    report
  • TomLiotta
    The documentation implies that SFLDSPCTL does not need to be on in order to display a subfile with one exception:
    • Note: SFLDSPCTL must be in effect when the subfile is displayed for an input operation to the subfile control record to be valid, even if there are no displayable fields in the subfile-control record format.
    I assume, then, that if no input operation is done to the control record, the option does not need to be enabled. But like others, I've never tried it nor seen it done. Nor can I think of a good reason for it. Tom
    125,585 pointsBadges:
    report
  • deepu9321
    I believe, you should be switching ON SFLDSPCTL indicator. SFLDSPCTL indicates the displaying the Control part of the Subfile. And, if you would like to display Subfile(With or With out Control Format Records), you must be using EXFMT with Control format Record format name. If your requirement is not to display the Fields available in Control format, you can have an indicator for Control format fields and switch it ON when you dont want Control format fields to be appear on Screen. Pradeep.
    3,695 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to:

To follow this tag...

There was an error processing your information. Please try again later.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Thanks! We'll email you when relevant content is added and updated.

Following