how can test oms400&ods400 on as400?
ASKED: August 4, 2009  8:59 AM
UPDATED: September 15, 2011  1:49 PM

Answer Wiki

Thanks. We'll let you know when a new response is added.

Are you talking HA software. Want to test a Link?
Create a PF on the source syste,see if ODS replicates the object to the target system, Then make a change to the physical file (add a member) to see if it changes on the target system.

Discuss This Question: 3  Replies

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • mcl
    OMS400/ODS400 is Vision Orion and it is HA software. The original question is a bit vague. If you have the software installed and configured then what MellOrman said will work fine. Any object will be replicated to the target as long as you have not put that object on a list of exceptions. If you are looking to test swapping source and target systems, then you will be doing what Vision calls a "Roleswap". Chances are you have a "ROLESWAP" user ID. Sign on with that and you get a ROLESWAP menu. Follow the menu options in order on both systems. If you want to test and see if the software is worth using? Well, we've been running it for four years. It works fine. Regards Mike
    2,740 pointsBadges:
    report
  • Whatis23
    There are a lot of components to OMS and ODS. For ODS, you should create a new test user profile and see if it gets added to your Target system. Then update the profile and check if the changes went through. Do the same with a spool file to a monitored outq. Just take a print screen and see if it goes across then delete and check that as well. There is just too much to cover without any specifics. For OMS, make a test link and create or copy a file with several 1000 records. Verify that gets syncronized. Then make several updates to the file (dlt recs, add recs., chgobjown, etc) and watch them go across to the Target.
    5,665 pointsBadges:
    report
  • Vaibhavj
    Enter OMS400 on cmd line ,put 8 infront on option.then enter you see all status on link.u must check date time For ODS400 Enter OdS400 on cmd line.put 3 on option and enter.and check all status
    10 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to:

To follow this tag...

There was an error processing your information. Please try again later.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Thanks! We'll email you when relevant content is added and updated.

Following