Hi All, I am new to the mainframe application development environment.Can anyone help me how to solve JCL Abends like say SOC7,SOC4. regards, Aravind
ASKED: October 26, 2005  5:33 AM
UPDATED: October 26, 2005  7:45 AM

Answer Wiki

Thanks. We'll let you know when a new response is added.

one is an error encountered when attempting to perform math ops on alpha data (that is in fields defined as num).

the other is an attempt to address memory outside the defined memory space of a task. common causes are parameter mismatch in call-using and proced-using, definition mismatch of passed/referenced areas, bad index-register manipulation.

if you would like specific help you can e-mail me directly at dick-brenholtz@t-online.de

Discuss This Question: 1  Reply

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • FabioMor
    I suggest you to look at the IBM Library (http://publibz.boulder.ibm.com/cgi-bin/bookmgr/library), where you can find some answers to the ABEND Codes. Anyway, you can find the explanation of the abnormal end codes by looking at the ABEND-AID report. In that report you can see the contents of the working area of the program, as well as the contents of the files you're reading/writting and the address of the program where the error occured. By the way, a S0C7 code usually is received when you're moving a non-numeric value to a numeric field or when you try to do a mathematic operation using a working field that was not initialized with "VALUE ..." (in COBOL). About S0C4, it's very common to occur when there is an area invasion in the working-storage section. For example, you have a table with 50 occurs and move a value to this table with a value greater than 50. But S0C4 can be a lot of other errors. I use to call S0C4 as the "else" of the ABENDS :-) Hope I could help you, a have a nice day.
    0 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to:

To follow this tag...

There was an error processing your information. Please try again later.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Thanks! We'll email you when relevant content is added and updated.

Following