I have the need to start my IBM webserver via a batch job. I attempted to use the $VS command to send the start command through the internal reader. However, since the IPCS parms are case sensitive, it didn't work because the case was not preserved. Is there a way to send a mixed case command through a batch job to the OS?

Software/Hardware used:
ASKED: December 2, 2005  5:24 PM
UPDATED: December 6, 2005  5:51 PM

Answer Wiki:
My suspicion is that you created this job in ISPF with CAPS ON. If so, re-edit the JCL: open the member, issue the command CAPS OFF, then retype the case sensitive information and save the job. Bill
Last Wiki Answer Submitted:  December 6, 2005  5:51 pm  by  TwoMetreBill   0 pts.
All Answer Wiki Contributors:  TwoMetreBill   0 pts.
To see all answers submitted to the Answer Wiki: View Answer History.