		<title>By: danmd5systemad</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/mq-series-for-as400/#comment-105232</link>
		<dc:creator>danmd5systemad</dc:creator>
		<pubDate>Thu, 22 Mar 2012 08:56:31 +0000</pubDate>
		<guid isPermaLink="false">#comment-105232</guid>
		<description><![CDATA[What&#039;s the use of MQSeries for AS/400? I&#039;ve got an issue with system generated scheduler running during our end of day batch as follows :

&lt;pre&gt;CPF1124  00  INFO         Job 737372/QMQM/AMQZLAA0 started on 03/06/12 at 00:58:12 in subsystem QMQM in QMQM. Job entered system on
                      AMQZLAA0   QMQM       737372                   03/06/12 00:58:12.459168 QMQM
CPF1124  00  INFO         Job 737373/QMQM/AMQCRSTA started on 03/06/12 at 00:58:12 in subsystem QMQM in QMQM. Job entered system on
                      AMQCRSTA   QMQM       737373                   03/06/12 00:58:13.153016 QMQM
CPF1164  00  COMPLETION   Job 737373/QMQM/AMQCRSTA ended on 03/06/12 at 00:58:13; 1 seconds used; end code 0
                      AMQCRSTA   QMQM       737373                   03/06/12 00:58:13.574704 QMQM
CPF1124  00  INFO         Job 737374/QMQM/RUNMQCHL started on 03/06/12 at 00:58:14 in subsystem QMQM in QMQM. Job entered system on
                      RUNMQCHL   QMQM       737374                   03/06/12 00:58:14.389336 QMQM
CPF1124  00  INFO         Job 737375/QMQM/RUNMQCHL started on 03/06/12 at 00:58:32 in subsystem QMQM in QMQM. Job entered system on
                      RUNMQCHL   QMQM       737375                   03/06/12 00:58:32.807664 QMQM
CPF1124  00  INFO         Job 737376/QPM400/Q1PPMSUB started on 03/06/12 at 01:00:05 in subsystem QSYSWRK in QSYS. Job entered syst
                      Q1PPMSUB   QPM400     737376                   03/06/12 01:00:06.003632 QPM400
CPF1164  00  COMPLETION   Job 737376/QPM400/Q1PPMSUB ended on 03/06/12 at 01:00:07; 1 seconds used; end code 0
                      Q1PPMSUB   QPM400     737376                   03/06/12 01:00:07.834840 QPM400
TCP2617  20  DIAGNOSTIC   TCP/IP connection to remote system 192.168.109.246 closed, reason code 2.
                      QTCPIP     QTCP       650790                   03/06/12 01:01:23.763352 QTCP
CPF1164  00  COMPLETION   Job 737374/QMQM/RUNMQCHL ended on 03/06/12 at 01:01:24; 1 seconds used; end code 0
                      RUNMQCHL   QMQM       737374                   03/06/12 01:01:24.052320 QMQM
CPF1164  00  COMPLETION   Job 737375/QMQM/RUNMQCHL ended on 03/06/12 at 01:01:42; 1 seconds used; end code 0
                      RUNMQCHL   QMQM       737375                   03/06/12 01:01:42.461064 QMQM
CPF1164  00  COMPLETION   Job 737372/QMQM/AMQZLAA0 ended on 03/06/12 at 01:01:43; 1 seconds used; end code 0
                      AMQZLAA0   QMQM       737372                   03/06/12 01:01:43.767024 QMQM&lt;/pre&gt;

All this QMQM related job is related to the MQSeries for AS/400 and I totaled all these QMQM jobs running, it totals to more than 1 hour which prolongs our end of day batch. If i can deactivate this, my end of day batch will be faster but when i consulted IBM, they say that this is not advisable since it may affect &lt;i&gt;&quot;mission-critical communication between applications, either within an organization or business to business.&quot;&lt;/i&gt; So now, im trying to understand the role of  MQSeries for AS/400. Thanks as usual guys.]]></description>
		<content:encoded><![CDATA[<p>What&#8217;s the use of MQSeries for AS/400? I&#8217;ve got an issue with system generated scheduler running during our end of day batch as follows :</p>
<pre>CPF1124  00  INFO         Job 737372/QMQM/AMQZLAA0 started on 03/06/12 at 00:58:12 in subsystem QMQM in QMQM. Job entered system on
                      AMQZLAA0   QMQM       737372                   03/06/12 00:58:12.459168 QMQM
CPF1124  00  INFO         Job 737373/QMQM/AMQCRSTA started on 03/06/12 at 00:58:12 in subsystem QMQM in QMQM. Job entered system on
                      AMQCRSTA   QMQM       737373                   03/06/12 00:58:13.153016 QMQM
CPF1164  00  COMPLETION   Job 737373/QMQM/AMQCRSTA ended on 03/06/12 at 00:58:13; 1 seconds used; end code 0
                      AMQCRSTA   QMQM       737373                   03/06/12 00:58:13.574704 QMQM
CPF1124  00  INFO         Job 737374/QMQM/RUNMQCHL started on 03/06/12 at 00:58:14 in subsystem QMQM in QMQM. Job entered system on
                      RUNMQCHL   QMQM       737374                   03/06/12 00:58:14.389336 QMQM
CPF1124  00  INFO         Job 737375/QMQM/RUNMQCHL started on 03/06/12 at 00:58:32 in subsystem QMQM in QMQM. Job entered system on
                      RUNMQCHL   QMQM       737375                   03/06/12 00:58:32.807664 QMQM
CPF1124  00  INFO         Job 737376/QPM400/Q1PPMSUB started on 03/06/12 at 01:00:05 in subsystem QSYSWRK in QSYS. Job entered syst
                      Q1PPMSUB   QPM400     737376                   03/06/12 01:00:06.003632 QPM400
CPF1164  00  COMPLETION   Job 737376/QPM400/Q1PPMSUB ended on 03/06/12 at 01:00:07; 1 seconds used; end code 0
                      Q1PPMSUB   QPM400     737376                   03/06/12 01:00:07.834840 QPM400
TCP2617  20  DIAGNOSTIC   TCP/IP connection to remote system 192.168.109.246 closed, reason code 2.
                      QTCPIP     QTCP       650790                   03/06/12 01:01:23.763352 QTCP
CPF1164  00  COMPLETION   Job 737374/QMQM/RUNMQCHL ended on 03/06/12 at 01:01:24; 1 seconds used; end code 0
                      RUNMQCHL   QMQM       737374                   03/06/12 01:01:24.052320 QMQM
CPF1164  00  COMPLETION   Job 737375/QMQM/RUNMQCHL ended on 03/06/12 at 01:01:42; 1 seconds used; end code 0
                      RUNMQCHL   QMQM       737375                   03/06/12 01:01:42.461064 QMQM
CPF1164  00  COMPLETION   Job 737372/QMQM/AMQZLAA0 ended on 03/06/12 at 01:01:43; 1 seconds used; end code 0
                      AMQZLAA0   QMQM       737372                   03/06/12 01:01:43.767024 QMQM</pre>
<p>All this QMQM related job is related to the MQSeries for AS/400 and I totaled all these QMQM jobs running, it totals to more than 1 hour which prolongs our end of day batch. If i can deactivate this, my end of day batch will be faster but when i consulted IBM, they say that this is not advisable since it may affect <i>&#8220;mission-critical communication between applications, either within an organization or business to business.&#8221;</i> So now, im trying to understand the role of  MQSeries for AS/400. Thanks as usual guys.</p>
]]></content:encoded>
	</item>
</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Page Caching using memcached
Database Caching 3/10 queries in 0.038 seconds using memcached
Object Caching 267/273 objects using memcached

Served from: itknowledgeexchange.techtarget.com @ 2013-05-25 09:42:01 -->