Failed to Convert Function Standard Synon to 64-Bits

15 pts.
Tags:
AS/400 upgrades
AS400 Data Definitions
Synon
V3R2
V5R2M0
I have successfully migrated AS400 from O/S V3R2M0 to V5R2M0. But currently having problems especially for objects standard synon (exmpl: Y2QLVNR, etc)which failed to be converted to 64 Bits. The error message is 'Program or module not observable' Any help greatly appreciated! Thank you Hendriyanto - Indonesia

Software/Hardware used:
-

Answer Wiki

Thanks. We'll let you know when a new response is added.

the version of software you are using as you say is not observable and will not convert.

You need to contact the software vendor and ask for an update for the operating system you are using.

There’s no other way arounf the problem unless you re-compile, which you probably can’t do as you won’t have the source code.

Discuss This Question: 3  Replies

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • RossHowatson
    Break down what objects did not get converted (this should have been tested before the system was converted upward). Either submit two jobs and look at the job log or bring up two screens and run the commands on one screen looking at the job log with the second screen. To find what files did not get conveted in what libraries issue the command: STROBJCVN LIB(*ALLUSR) OBJTYPE(*FILE) To find what programs did not get conveted in what libraries issue the command: STROBJCVN LIB(*ALLUSR) OBJTYPE(*ALLPGM) Change the *ALLUSR parameter to a particular library and it will only do this library. If you have the source code you need to recompile the program and then ship this over to the new machine (if required). If you do not have the source code then you will have to either rewrite the program in question or get this from an outside source.
    265 pointsBadges:
    report
  • TomLiotta
    (this should have been tested before the system was converted upward). That would be tricky since ...migrated AS400 from O/S V3R2M0. Regardless, a Synon program named "Y2QLVNR" is simply unlikely to convert. The conversion needs to be done by the vendor. It's possible that it doesn't matter. If the program is part of the generator processes and not part of the generated application run-time, it probably will never be used. It would only be relevant if the product is licensed and upgraded to run on V5R2. And if it's not licensed, then the conversion shouldn't be done anyway. Tom
    125,585 pointsBadges:
    report
  • Syifa123natasha
    Thanks Tom-san & Ross Howatson-san. Y2QLVNR is one of objects in synonlibs library. Mostly those objects include in our add-on programs which generated by synon system. If the application just only process, I do skip that object & recompile that application. This is one of solution. But if the program is input program & use subfile, almost impossible.. Rgds Hendriyanto
    15 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to: