55 pts.
 CPF1236
What would cause CPF1236 to be issued for an overnight job we submit via a CL program? CPF1236 is "Subsystem &1 cannot start prestart job &2."

Software/Hardware used:
ASKED: June 20, 2008  1:24 PM
UPDATED: June 20, 2008  3:50 PM

Answer Wiki:
if you look at the second level text for this message it says Cause . . . . . : User profile &5 named in the prestart job entry for program &3 in library &4 is not authorized to job description &6 in &7. this is therefore an authority issue Recovery . . . : Have the security officer grant *USE authority (GRTOBJAUT command) for the job description to the user profile.
Last Wiki Answer Submitted:  June 20, 2008  3:50 pm  by  Teckgeck   170 pts.
All Answer Wiki Contributors:  Teckgeck   170 pts.
To see all answers submitted to the Answer Wiki: View Answer History.