	<item>
		<title>By: gilly400</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/cpf0006-during-sbmjob-cool-2e-generated-code/#comment-59804</link>
		<dc:creator>gilly400</dc:creator>
		<pubDate>Tue, 10 Feb 2009 13:33:02 +0000</pubDate>
		<guid isPermaLink="false">#comment-59804</guid>
		<description><![CDATA[Hi,

Have you tried doing a CHGJOB to get maximum logging and checking what the joblog says :-

CHGJOB LOG(4 00 *SECLVL)  LOGCLPGM(*YES)

Regards,

Martin Gilbert.]]></description>
		<content:encoded><![CDATA[<p>Hi,</p>
<p>Have you tried doing a CHGJOB to get maximum logging and checking what the joblog says :-</p>
<p>CHGJOB LOG(4 00 *SECLVL)  LOGCLPGM(*YES)</p>
<p>Regards,</p>
<p>Martin Gilbert.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: gokulvirtual</title>
		<link>http://itknowledgeexchange.techtarget.com/itanswers/cpf0006-during-sbmjob-cool-2e-generated-code/#comment-59802</link>
		<dc:creator>gokulvirtual</dc:creator>
		<pubDate>Tue, 10 Feb 2009 12:29:22 +0000</pubDate>
		<guid isPermaLink="false">#comment-59802</guid>
		<description><![CDATA[Actually i missed out WSDEC while typing this question... Typo...
The above mentioned cobol code is generated while compiling the code on SYNON COOL 2E. 
The parameters given for SBMJOB in SYNON code is parsed as this during the compilation.

I have read in some old thread of the same issue( year 1999) that , Y2BLSJR have issues for the last parameter if the SYNON program has passed the parameters as FLD during SBMJOB. 

But its a surprise for me whether it is still not fixed ?

Please explain.. Thanks..]]></description>
		<content:encoded><![CDATA[<p>Actually i missed out WSDEC while typing this question&#8230; Typo&#8230;<br />
The above mentioned cobol code is generated while compiling the code on SYNON COOL 2E.<br />
The parameters given for SBMJOB in SYNON code is parsed as this during the compilation.</p>
<p>I have read in some old thread of the same issue( year 1999) that , Y2BLSJR have issues for the last parameter if the SYNON program has passed the parameters as FLD during SBMJOB. </p>
<p>But its a surprise for me whether it is still not fixed ?</p>
<p>Please explain.. Thanks..</p>
]]></content:encoded>
	</item>
</channel>
</rss>

<!-- Performance optimized by W3 Total Cache. Learn more: http://www.w3-edge.com/wordpress-plugins/

Page Caching using memcached
Database Caching 3/10 queries in 0.043 seconds using memcached
Object Caching 280/286 objects using memcached

Served from: itknowledgeexchange.techtarget.com @ 2013-05-19 18:09:38 -->