Hi Everyone! I'm completely new with AS/400 so please bare with me. anyway I'm a security engineer and would like to monitor config files of as400 What I want first to do is to transfer the .savf i have to as400 from windows server 2008 via ftp. Which is good actually i don't have any problems in transferring but after I do the commands CD /QSYS.LIB/DATA.LIB BINARY MPUT SAVF.SAVF (REPLACE you will receive prompt : MPUT SAVF.SAVF? (Enter a "Y") EXIT I tried to check the content of SAVF.SAVF but I cannot see it. I really forgot what the error says but it is more on error in version or CD-ROM... not installed properly my question is do I need to execute something in order to retrieve/read the .SAVF file or my file is really corrupted? thanks. <3 jez@

Answer Wiki

Thanks. We'll let you know when a new response is added.

TOM- the .savf files was established by one of our professional services and from where? that I do not know.. so basically tom what are you trying to say is when this .savf files comes to different as400 and is not compatible to the new as400 this might be the reason? thanks.
BIGKAT-I would like to monitor AUTL, CFGL,CNNL CTLD JOBD LIND which more of them are lists and description.. what we do is to get the original details of each objects and monitor it if someone makes some addition,deletion or modification in the line.thanks
RICKMCD- I’m assisting the AS400 admin for this but for the inputs he’s the one doing it. I truly believe he knows what to do.thanks

Discuss This Question: 4  Replies

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when members answer or reply to this question.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy
  • TomLiotta
    First, was there a reason you used MPUT instead of PUT? It doesn't matter for the content, but a simple PUT is usually easier for transfers of single files.   Anyway, without the error message identifier, there is almost nothing we can say. If we don't know what the system thinks is wrong, we can't guess how it might be fixed.   Two general areas need to be reviewed. First, how did the savefile get to the Windows system in the first place? If it wasn't a binary transfer, then it was corrupted at that time. Second, where did the savefile originally come from? If it came from a different AS/400, it might contain data items from an incompatible system version.   But without more details, we don't know.   Tom
    125,585 pointsBadges:
    report
  • BigKat
    Also, you may want to expand on what you are trying to do when you say "to monitor config files of as400" (which may need to splinter off into its own question for traceability reasons - but start here and we'll see where it goes)
    7,935 pointsBadges:
    report
  • Rickmcd
    Since you are new to Iseries, did you use right command to look at save file, DSPSAVF data/savf
    1,595 pointsBadges:
    report
  • TomLiotta
    Objects in a savfile were created for a given OS version. If an object is at version "X", then it is often not compatible with version "(X-1)". However, the OS generally allows you to specify that an object is to be saved for a previous version as long as the target version is not more than two releases behind and the object does not have an attribute that doesn't exist in the target release.   A system might be at OS level 7.1 and various objects might be requested to save at OS level 6.1 successfully. Those objects could then be restored to a 6.1 system. The savefile would have attributes that a 6.1 system would accept. A V5R4 system would reject that savefile.   That's not true for all object types. For system configuration objects, there is no way to specify a target release. The intention is only to save for disaster recovery, not to make available for use on a different system.   I'm a little confused, though. The list of objects that you gave doesn't really fit with what might make sense. A number of those are older 'legacy' things that aren't reasonable to save/restore for testing. There is no way to look at them via a savefile; they must actually be restored which replaces that system's configuration. (Some of them aren't generally even used anymore.)   Also, the list contains incompatible objects. There would be at least three separate savefiles for *AUTLs, *CNNLs and *JOBDs for example. Of those three, only *JOBDs might reasonably be restored in a way that would allow some kind of testing or monitoring. And a restore would be the only action that would make "monitoring" feasible.   In short, it's still not clear what you're actually trying to accomplish. It's pretty certain that whatever it is, there's a much better way to do it.   Tom
    125,585 pointsBadges:
    report

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to:

To follow this tag...

There was an error processing your information. Please try again later.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Thanks! We'll email you when relevant content is added and updated.

Following