Onboard Administrator failing in HP BladeSystem

Raj Perumal Raj Perumal Profile: Raj Perumal

So here’s a little issue you might run into with an HP C7000 BladeSystem. In this scenario you have two Onboard Administrators which manage the Blade enclosure and all of it’s components. One is an active OA (Onboard Administrator) and one is passive.

You try to power on one of the blades and you get a power error and the red light flashes on front of the blade. You login to the OA and you see that everything is not good. There is a critical error with the power subsystem. You then check the enclosure info on the LCD and it tells you the other OA is the active one. Now that’s strange because the one you’re connected to thinks it’s the active one. How do you fix this?

Pull the bad OA, and call HP support and have it replaced. When you put the new OA in everything should go back to normal. Basically I had a bad OA that thought the power subsystem was not working but that wasn’t the case, it was the OA that was the issue.

Once the OA was replaced, all the blades powered up fine. Hope this helps!

-Cheers, RP

 Comment on this Post

 
There was an error processing your information. Please try again later.
Thanks. We'll let you know when a new response is added.
Send me notifications when other members comment.

REGISTER or login:

Forgot Password?
By submitting you agree to receive email from TechTarget and its partners. If you reside outside of the United States, you consent to having your personal data transferred to and processed in the United States. Privacy

Forgot Password

No problem! Submit your e-mail address below. We'll send you an e-mail containing your password.

Your password has been sent to: